Features
- Field proven, reliable since 1992.
- Stable, bright 7 segment LED display.
- Exclusively developed at Syntron for utter reliability under industrial conditions.
- Digital Meter Set point Relays for Amps and those for KW (or HP) are used as economical MD controllers.
- Appropriately scaled Process parameter indicators are available for 0-5V DC input and for 4-20mA DC input.
- Watt meters and var meters are based on four quadrant time shared multiplier principle for accurate true RMS measurement at all power factors.
- All meters are available for Auxiliary supply of 230V AC. 110V AC version are also available.
- Voltmeters also available for PT operated HT applications.
- Integrator based Frequency meter shows steady display.
- Output contacts are rated for maxima of 230V AC 50Hz and 5Amps resistive load.
Digital Meters Set Point Relay for Voltage (type MRD-V)

These instruments are accurate and are characterized by steady bright 7-segments 12.7 mm LED display and are available in compact size of 96 x 96 x 150 mm. Normally available for range of 0 600V AC, the digital voltmeter set point relays are also available for ranges from 0-200mV, 0-200V, direct reading DC or AC. They are also available for PT operated HT applications in ranges of 3.3KV, 6.6KV, 33KV, 66KV, 132KV and 220KV. Ripple integration provided in DC meters gives stable display for bridge rectified power supplies.
Digital Meter Set Point Relay for Current (type MRD- A)

These instruments are accurate and are characterized by steady bright 7-segment 12.7mm LED display and are available in compact size of 96×96x150mm. Normally available for CT operated AC application, the Ammeter is also available for ranges of 0-2mA, 0-20mA, 0-2mps and 0-5Amps, direct reading DC or AC. These instruments are very successfully used as Demand Controllers at a fraction of the cost of other so called Maximum Demand Controllers that provide a lot of unnecessary features to increase the cost.
Digital Meter Set Point Relay for Frequency (type MRD-F)

These instrument are accurate and are characterized by steady bright 7-segment 12.7mm LED display and are available in compact size of 96×96x150mm. It is designed to accept wide-ranging voltage input from 50V to 600V. Available for the Mains Frequency range of 45.0-55.0Hz, the display is exceptionally steady compared to some other makes of frequency meter that are based on counting circuits. The Syntron Frequency Meter Set Point Relay is based on a built in frequency to voltage transducer. The output of the transducer being integrated for conversion to digital is steady, and accurate.
Digital Meter Set Point Relay for W, KW and MW (type MRD1P1EW, MRD3P2EW, MRD3P3EW)

These instruments are accurate and are characterized by steady bright 7-segemnt 12.7mm LED display and are available in compact size of 96×96x150mm. Time shared four-quadrant multiplier technology is used for true RMS, accurate measurement at all power factor. The instruments are available in single-phase single element (type MRD1P1EW), three phase double element (type MRD3P2EW) and three phase triple element (type MRD3P3EW) versions, for LT as well as HT applications. These instruments are very successfully used as Demand Controllers at a fraction of the cost of other so called Maximum Demand Controllers that provide a lot of unnecessary features to increase the cost.
Digital Meter Set Point Relay for var, Kvar and Mvar (type MRD3P2VAR)

These instruments are accurate and are characterized by steady bright 7-segement 12.7mm LED display and are available in compact size 96×96x150mm. Time shared four-quadrant multiplier technology is use for true RMS, accurate measurement at all power factor. The instrument are available in three phase double element version only (type MRD3P2VAR). The instrument are available for LT as well as HT applications.
Power Factor Alarm Relay (type MRD-PF)

These instruments are accurate and are characterized by steady bright 7-segment 12.7mm LED display and are available in compact size of 96 x 96 x 60mm. The instrument is designed for application in manually controlled power factor improvement systems. Microcontroller based, the instrument provides accurate measurement of power factor (cos x) and a display of three-and-a-half digits from 0.000 to 1.000.separate indications by LEDs are provided for lag and lead. Alarm limits are factory programmed. Standard version has lag setting of 0.96 and lead setting of 0.99. Time delays of 10 seconds are programmed into the standard version for lag as well as lead. Two relays are provided inside one one for lag and the other for lead. The lag relay operates when the power factor goes lagging and below the lag setting, for the programmed time. Similarly for the lead relay.
Microcontroller Intelligent Kvar Control Relay (type MRD-CAP)

Designed specially for dedicated load PF correction such as for a compressor or conveyor. The Relay is also used for correction of power factor on HT by switching a capacitor on LT for economical control. Shows digital indication of instantaneous Kvar. It has separate setting for lag and lead Kvar. Available in compact size of 96 x 96 x 110mm.